![Manual Manual](https://www.manualsdir.com/manuals/56806/10/bea-horton-c2150-page10.png)
USER GUIDE
1 Description
Terminal | Narrow Antenna Storage | Manual Set-Up Buttons | Wire Opening Knockout | Opening Tab |
Block | (inside the cover) |
Wire Passage Hole | Planar Antenna | Lateral and Angle | Front Cover | LED |
Adj. For Antenna |
NOTE: For mounting heights between 10’ and 16’, use BEA model 10EAGLEHM (high mount).
Sensing systems that count, record and analyze pedestrian traffic flows to maximize the efficiency of a building's setup and ensure that inventory placement is maximized. Horton c4190 control board diagram compiled pdf, horton c4190 control board diagram - Direct Download: best 250 trail boss manual b7300hst 4x4 parts warrior leader course test answers arc 222 vhf radio contract Horton c2150 manuals - page 2 - usersmanuals1.com document outline. 80.0005horton c2150 control with eagles, iris,microcell 1.
2 | Technical Specifications | |
DESCRIPTION | SPECIFICATION | |
Frequency: | 24.125 GHz | |
Supply voltage: | 12 to 24 V AC: ± 10%: | |
12 to 24 V DC: -10% / +30%: | ||
Mounting height: | Normal: 7’; Maximum: 10’-0” | |
Tilt angle: | 0° to 90° vertical | |
-15° to +15° lateral | ||
Detection area: | 13ft (W) x 6.5ft (D) | |
Wide | ||
Narrow | 6.5ft (W) x 8.2ft (D) (supplied as optional) | |
Minimum detection speed: | 2 in/sec. (measured in axis) | |
Power consumption: | < 2 W | |
Standard output relay: | ||
Max contact voltage | 60 VDC / 125 VAC | |
Max contact current | 1 A (resistive) | |
Max switching power | 30W (DC) / 60VA (AC) | |
Hold time: | 0.5 sec. to 9 sec. (adjustable) | |
Temperature range: | -4°F to 131°F | |
Dimensions: | 4.75in (W) x 3.15in (H) x 2.0in (D) | |
Weight: | 0.5lbs | |
Material: | ABS | |
Housing color: | Black. Can be painted with non-metallic paint | |
Cable length: | 6ft |
Blink mac system font download. 75.5185.04 20070727 | Page 1 of 8 |
1 Tips
The sensor must be firmly fastened to prevent vibration.
The sensor must not be placed directly behind a panel or any kind of material.
The sensor must not have any object likely to move or vibrate in its sensing field.
The sensor must not have any fluorescent lighting in its sensing field.
Horton C2150 Controller Programming Manual Free
2 Safety Precautions
•Shut off all power going to the header before attempting any wiring procedures.
•Maintain a clean & safe environment when working in public areas.
•Constantly be aware of pedestrian traffic around the door area.
•Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
•Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.
•Ensure compliance with all applicable safety standards upon completion of installation.
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body’s charge.
CAUTION: In the event a unit needs to be opened, observe the following precautions.
Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body.
Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity.
Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag.
3 | Mechanical Installation |
Opening the sensor | |
From behind, before installation | From the front, after installation |
Horton C2150 Controller Programming Manual Pdf
Mounting the sensor
Horton C2150 Control Board
or | ||||
Paste the template at desired | Insert screws but do not screw | Optional cable routing: | ||
location. | them fully in. | Notch the cover as shown in | ||
Drill as instructed. | Pass the cable where | the picture. | ||
indicated. |
4 | Electrical Installation | ||||||||
Terminal | Connection | ||||||||
1 | (Red) | 12 to 24 | VAC / DC (+) | ||||||
2 | (Black) | 12 to 24 | VAC / DC (-) | ||||||
3 | (White) | Relay Common | |||||||
4 | (Green) | Relay N.O. | |||||||
5 | Relay N.C. | ||||||||
Note: Input power | tolerance is +/- 10% for | ||||||||
AC, and -10% to +30% for DC power. |
Horton C2150 Controller Programming Manual 2017
Run the cable through the wire | Position the sensor and tighten the | Wiring connections are as shown above. |
passage hole just below PCB. | two screws. Make sure you leave | |
enough cable to reach the terminal | ||
block near the top of the sensor. |
Horton C2150 Controller Programming Manual Online
75.5185.04 20070727 | Page 3 of 8 |
Horton C2150 Controller Programming Manual Download
Name | Resource Type | Catalog Number | Download |
---|---|---|---|
LightLEEDer Operation Manual | User Manuals | LL-4, LL-8, LL-16, LL-24, LL-32, LL-40, LL-48, LL-56, LL-64 | |
LightLEEDer Quick Reference Guide | User Manuals | LL-4, LL-8, LL-16, LL-24, LL-32, LL-40, LL-48, LL-56, LL-64 | |
LightLEEDer Quick Installation Guide | User Manuals | LL-4, LL-8, LL-16, LL-24, LL-32, LL-40, LL-48, LL-56, LL-64 | |
LightSync G2 Multi-Zone Dimmer Programming Guide | User Manuals | LS-G2 | |
Apprentice 3 Lighting Control Panel User Manual | User Manuals | AP3-4, AP3-8, AP3-16, AP3-24, AP3-32 | |
Apprentice 3 Quick Reference Guide | User Manuals | AP3-4, AP3-8, AP3-16, AP3-24, AP3-32 | |
LightLEEDer Pro Network Software Manual | User Manuals | LightLEEDer Pro System Programming Software | |
LightSync Conditional Input Software Manual | User Manuals | LSCIM-P, LSCIM-R | |
LightSync Digital Touch Screen Station 2 Software Manual | User Manuals | LS-TSS2-XX-3.5, LS-TSS2-XX-4.3, LS-TSS2-XX-7.0 | |
LightSync Touch Screen Configuration Software Manual | User Manuals | LS-TSS-XX-4.3, LS-TSS-XX-7.0 | |
LightLEEDer Insite User Manual | User Manuals | INSITE-LL-S | |
Mobile LightSync Link App Programming Guide | User Manuals | Mobile LightSync Link App |